17.3.5.1 The One-Sample Variance Test Dialog Box
Contents
Supporting Information
To open the One-Sample Test for Variance dialog box:
- With the worksheet active, click Statistics: Hypothesis Testing: One-Sample Variance Test...
See Also:
Input
One-Sample Variance Test supports Raw, Summarized Data(SD) and Summarized Data(Variance) three input data form.
| Raw | Enter column with range format.
For help with range controls, see: Specifying Your Input Data |
|---|---|
| Summarized Data (SD) | Summarized Data is standard derivation and sample size prepared for samples.
Enter following Summarized Data by selecting columns from worksheet or entering into the dialog box manually.
|
| Summarized Data (Variance) | Summarized Data is Variance and sample size prepared for samples.
Enter following Summarized Data by selecting columns from worksheet or entering into the dialog box manually.
|
Test
| Test for | Options:
|
|---|---|
| Test Variance | If select Variance in Test for drop-down list, you can specify the hypothetical variance to be tested. |
| Test SD | If select Standard Deviation in Test for drop-down list, you can specify the hypothetical SD to be tested. |
| Null Hypothesis | The null hypothesis to be tested (i.e. sample variance = Test Variance). |
| Alternate Hypothesis | Options:
|
| Significance Level | The significance level of the test. |
| Confidence Interval(s) | Compute confidence intervals for sample variance. |
| Confidence Level(s) in % | Specify space-separated confidence levels (%). This option is only available when Confidence Interval(s) is selected. |
| Test Method | Select test method
|
Power Analysis
Unset Minimal Difference of Interest
| Difference(s) for Specified Power | When Minimal Difference of Interest is not set, this option is available.
Output the differences for the specified power levels. When this option is selected, the specified power levels setting will affect the power level in power curve. |
|---|---|
| Power Level(s) | When check the Difference(s) for Specified Power option, you can enter the power levels separated by space in this edit box. Default power levels are 60%, 70%, 80% and 90%. |
Set Minimal Difference of Interest
| Minimal Difference of Interest | Specify the minimum difference from the test variance/SD and the target variance/SD. Once you enter a value in this box, the Power Analysis graph will show the minimum sample size to detect this difference in the different powers. |
|---|---|
| Sample Size(s) for Specified Power | When check the Minimal Difference of Interest option, this option is available.
Output the Sample Sizes for the specified power levels. When this option is selected, the specified power levels setting will affect the power level in power curve. If it is selected, it will use the default power levels. |
| Power Level(s) | When check the Sample Size(s) for Specified Power option, you can enter the target power levels separated by space in this edit box. Default power levels are 60%, 70%, 80% and 90%. |
| Power Based on Test Data | When specify the Minimal Difference of Interest, this option is available.
Compute the power for the sample size of the test data. (the probability of rejecting the null hypothesis when it is false). |
| Hypothetical Power | When specify the Minimal Difference of Interest, this option is available.
Compute the power of the test at various sample sizes. When check this option, it will add corresponding curve to power curve. |
| Hypothetical Sample Size(s) | When specify the Minimal Difference of Interest and Hypothetical Power is checked, this option is available.
Specify hypothetical sample size(s) for power computation. |
Plots
| Histogram | Plot a histogram of sample data. |
|---|---|
| Box Chart | Plot a box chart of sample data.
Note: When outlier(s) detected in the datasets, a footnote will show under the Box chart to note you to review their case. If you want to exclude the outliers, you can click the triangle button at the end of the footnote to mark outliers and recalculate. |
| Arrange Plots of Same Type in One Graph | Put the plots of same type in one graph. Note that for histograms, the layers will be arranged vertically; for box charts, layers will be arranged horizontally. |
| Note: When input data form is Summarized Data(SD)/(Variance), it will not output above plots. |
Output
| Results Log Output |
Select to output results to the Results Log. |
|---|---|
| Graphical Summary Report | Create a summary graph report, including P value bar, effect size bar and data distribution graph. The result tables will also been attached to the graph to show the statistical values.
The footnote after the summary graph will diagnose these statistical results. |
| Graphical Power Analysis Report | Specify whether to display the graphical Power Analysis report. The power curve shows how the statistical power of the test changes as the difference in proportions varies. Power is the probability of rejecting the null hypothesis when the true difference differs from 0.
A footnote will be added after the power curve graph to show you the diagnosis results of power analysis. A power value of 80% is usually considered sufficient. |
| Output Plot Data | Specify a worksheet for output of plotted data (Origin generates tabular data when plots are created). |
| Output Results | Specify the worksheet for output of test results. |
Note:
|